Other PPEs Home > Other PPEs
ICU VENTILATOR
  • ICU VENTILATOR
  • ICU VENTILATOR

ICU VENTILATOR

ICU Ventilator for non-invasive and invasive respiratory life support for pre-hospital emergency hospital transfer; anesthesia recovery room, emergency room; emergency center, etc.
$18500.00
INQUIRY




Technical parameters of first aid transfer ventilator
1. Scope of application:
  For non-invasive and invasive respiratory life support for pre-hospital emergency hospital transfer; anesthesia recovery room, emergency room; emergency center, etc.
2. Technical parameters:
1. Pneumatic electronically controlled ventilator
2. ▲ With touch screen, you can control the machine by touch
3. ▲ With voice navigation and alarm functions, Chinese voice prompts when the alarm occurs at startup, which is convenient for medical staff to grasp
4. ▲ One-key can quickly set the newborn, child and adult modes, quickly enter the rescue state
5. Screen specifications
5.1 Color TFT LCD anti-halo screen (with manual and automatic brightness adjustment function)
5.2 Screen size ≥ 7 inches
5.3 Resolution ≥800 × 480 pixels
5.4 ≥160 ° viewing angle
6. Optional triple function of breathing, negative pressure suction, mask oxygen supply
7. ▲ CPR function, cardiopulmonary resuscitation guidance and automatic ventilation function (single / double / continuous three modes)
8. ▲ RSA function, rapid induction of airway intubation and ventilation function (pre-oxygenation / intubation reminder / intubation ventilation)
9. ▲ Patient breathing valve: Electronically controlled high-precision positive end-expiratory pressure and continuous positive airway pressure
10. ▲ Patient end flow sensor: Realize breathing flow monitoring and precise control of breathing trigger
11. Alarm function: one-key setting of alarm parameters, alarm reset, alarm log display function
12. Standard portable first-aid kit, portable, one-shoulder, can be directly hung on a stretcher cart or hospital bed
13. Control modes: volume-controlled ventilation, pressure-controlled ventilation, non-invasive ventilation, advanced ventilation and resuscitation ventilation
14. ▲ Breathing modes: IPPV, V-AC, V-SIMV, PRVC, PRVC +, PCV, P-AC, P-SIMV, CPAP, CPAP +, BiPPV, BiPPV +, APRV, APRV +, CPR, RSA
15. ▲ Host weight: ≤5.5Kg
16. Working pressure: 2.7 ~ 6.0bar
17. Working environment:
18.1 Temperature range: -20 ° C ~ 60 ° C (storage -40 ° C ~ 70 ° C)
18.2 Humidity: 15% ~ 95%
18.3 Air pressure: 70kPa ~ 110kPa
18. Breathing time ratio: adjustable from 59: 1 to 1:99, step 0.1
19. ▲ Tidal volume: 20ml ~ 2500ml
20. The suction pressure is 3cmH2O ~ 60cmH2O
21. Trigger mode: pressure trigger / flow rate trigger
Pressure trigger -20cmH2O ~ 20cmH2O
Flow rate trigger 1L / min ~ 15L / min
22. ▲ Built-in electronic PEEP function, PEEP pressure 0 ~ 30cmH2O
23. ▲ With PSV function, support pressure 0,3cmH2O ~ 35cmH2O
24. Pressure rise time adjustment control, the range is 0.1s ~ 2s
25. Maximum ventilation flow: not less than 150 liters / minute
26. Respiratory frequency range: 1 ~ 120bpm
27. Oxygen concentration adjustment range: 40-100%, step 10%, error ± 10%
28. ▲ Monitoring indicators: oxygen concentration, carbon dioxide, respiratory rate, inhaled / exhaled minute ventilation, inhaled / exhaled tidal volume, airway pressure (peak pressure, average pressure, plateau pressure, PEEP pressure)
29.1 Oxygen battery monitoring without oxygen cell
29.2 Waveform: P + F + V, P + F + C, P + V + C, P + F waveform
29.3 Optional ring diagram: (P-V), (F-V), (F-P) ring diagram
29.4 Optional respiratory mechanics parameters and trend graph
29. Maximum breathing pressure: 15 ~ 70cmH2O can be set arbitrarily
30. Specifications of the air source connection pipe of the ventilator: external thread 9 / 16-18 and two kinds of quick insertion
31. Breathing hose connector: inner Φ15mm / outer Φ22mm
32. ▲ Rechargeable lithium battery, support hot swap
33.1 The battery can be charged online
33.2 Capacity: 7.8 Ah, Working time: ≥8 hours
33.3 Built-in backup battery, after disconnecting the main battery, it can still work for 20 minutes
33.4 Battery working temperature -20 ℃ ~ 60 ℃
33.5 Battery charging temperature 5 ℃ ~ 40 ℃
33. Respiratory system compliance: ≤100ml / cmH2O
34. Patient valve resistance:
35.1 Inhalation: <6mbar, when the flow rate is 30, 60 l / min
35.2 Exhalation: <6mbar, when the flow rate is 30, 60 l / min
35.3 Emergency suction air inlet: <6mbar, when the flow rate is 15, 30 l / min
35. Mechanical safety valve: ≤100cmH2O
36. Overall power: ≤50VA
37. Waterproof protection level: IPX4
38. Passed the European CE certification
39. Passed EN1789 vehicle test certification, with international certification